Surfix® models available: | Surfix® FN for measurements on iron/steel and on non-ferrous metals Surfix® F for measurements on steel/iron Surfix® N for measurements on non-ferrous metals Surfix® FN basic for measurements on iron/steel and on non-ferrous metals (without data memory, limits, interface, statistical functions) Surfix® F basic for measurements on steel/iron (without data memory, limits, interface, statistical functions) Surfix® N basic for measurements on non-ferrous metals (without data memory, limits, interface, statistical functions) |
Measuring principle: | magnetic induction principle (F version) eddy-current principle (N version) |
Measuring range: | 0 ... 1500 µm / 0 ... 60 mils (measuring unit operator-selectable) |
Tolerance: | ± (1 µm + 1% of reading) / ± (0.04 mils + 1% of reading) related to PHYNIX standards |
Resolution: | 0.1 µm / 0.004 mils or < 0.2% of reading |
Display: | back-light, 4-digit alphanumeric, digit height 10 mm / 0.4" |
Minimum measuring area: | 5 mm x 5 mm / 0.2" x 0.2" |
Minimum curvature radius: | convex 1.5 mm/60 mils, concave 5 mm/200 mils |
Minimum substrate thickness: | type F: 0.2 mm / 8 mils; type N: 50 µm / 2 mils |
Calibration: | factory calibration, zero calibration, foil calibration |
Statistics: | number of readings, mean value, standard deviation, maximum and minimum reading of max. 10 000 readings |
Data memory: | max. 200 readings, available singly; statistical values |
Limits: | adjustable with acoustic alarm system |
Operation temperature: | 0 °C to 50 °C/ 32 °F to 122 °F |
Surface temperature: | -15 °C to 60 °C/ 5 °F to 140 °F (briefly above 60 °C/140 °F up to 150 °C/302 °F) |
Storage temperature: | -20 °C to +60 °C / -4 °F to 140 °F |
Power supply: | 2 Mignon cells(AA) 1.5 V, up to 60 h battery life |
Dimensions: | gauge: 137 mm x 66 mm x 23 mm / 5.4" x 2.6" x 0.9" probe: 14 mm dia. x 83 mm / 0.56" dia. x 3.3" |
Weight: | 205 g / 7.2 ozs incl. batteries |
Protection class: | IP 52 (proof against dust and dripping water) |