Device type: | coating thickness gauge to be connected to separate, exchangeable probe |
Probes: | FN 1.5 for measurements on all metals range 0 - 1500 µm/0 - 60 mils
F 1.5 for measurements on iron/steel range 0 - 1500 µm/0 - 60 mils
N 1.5 for measurements on non-ferrous metals range 0 - 1500 µm/0 - 60 mils
FN 3.5 for measurements on all metals range 0 - 3500 µm/0 - 140 mils on iron/steel 0 - 3000 µm/0 - 120 mils on non-ferrous metals
F 3.5 for measurements on iron/steel range 0 - 3500 µm/0 - 140 mils
F 10 for measurements on iron/steel range 0 - 10 mm/0 - 400 mils
FN1.5/90° angled probe for measurements within tubes or grooves; for measurements on all metals range 0 - 1500 µm/0 - 60 mils
FN 0.2 special probe for very thin coatings; for measurements on all metals range 0 - 200 µm/0 - 8 mils
|
Measuring principle: | Magnetic induction method (F version) Eddy current method (N version) |
Tolerance: | ± (1 µm/0.04 mils + 1 % of reading) for FN 1.5, F 1.5, N 1.5, FN1.5/90°
± (2 µm/0.08 mils + 1 % of reading) for FN 3.5, F 3.5
± (3 µm/0.12 mils + 1% of reading) for F 10
± (0.7 µm/0.03 mils + 1% of reading) for FN 0.2
(referred to PHYNIX standards) |
Resolution: | 0.1 µm/0.004 mils or < 0.2 % of reading for FN 1.5, F 1.5, N 1.5, FN1.5/90°, FN 0.2
1 µm/0.04 mils or < 0.2 % of reading for FN 3.5, F 3.5, F 10
|
Display: | 4-digit display digit height 10 mm / 400 mils 32 alphanumerical characters switchable backlight selectable between µm/mils |
Confirmation of reading: | acoustically and optically |
Minimum area of measurement: | FN 1.5, F 1.5, N 1.5, FN1.5/90°, FN 0.2: 5 mm x 5 mm/200 mils x 200 mils
FN 3.5, F 3.5: 10 mm x 10 mm/400 mils x 400 mils
F 10: 20 mm x 20 mm/800 mils x 800 mils
|
Minimum radius of curvature: | FN 1.5, F 1.5, N 1.5, FN 0.2: convex 1.5 mm/60 mils, concave 5 mm/200 mils
FN 3.5, F 3.5: convex 5 mm/200 mils, concave 50 mm/2 inch
F 10: convex 5 mm/200 mils, concave 16 mm/640 mils
|
Minimum ID tube measurement: | FN1.5/90°: 12 mm/500 mils |
Minimum thickness of substrate: | FN 1.5, F 1.5, N 1.5, FN1.5/90°, FN 0.2: iron/steel: 0.2 mm/8 mils non-ferrous metals: 50 µm/2 mils
FN 3.5, F 3.5: iron/steel: 0.5 mm/20 mils non-ferrous metals: 0.1 mm/4 mils
F 10: iron/steel: 1 mm/40 mils
|
Calibration methods: | ·Factory calibration: no calibration required for standard applications · Zeroing (1-point calibration): measurements on small geometries · Zeroing and foil calibration (2-point calibration): increased measuring accuracy · Two-foil calibration: especially for rough, sand-blasted surfaces · Cal-Through-Coat-Calibration: calibration without uncoated test object · Zero offset: addition/subtraction of a constant value to/from the reading |
Limit values: | Freely selectable; optical and acoustic signal if limit value is exceeded |
Scan mode: | For continuous measurements; for the quick recognition of coating thickness variations; with permanent display of minimum and maximum reading |
Statistics: | Single-value statistics: number of readings, mean value, standard deviation, maximum and minimum reading, kvar, cp, cpk from max. 10000 readings
Block-value statistics: number of readings, mean value, standard deviation, maximum and minimum reading, kvar, cp, cpk; block size 3 to 100 readings |
Histogram: | calculate the data histogram according to the gauge limit setting and print it on portable printer Printfix |
Data memory: | 10000 readings in max. 250 freely selectable files; alphanumerical file names; saved readings and statistical values individually recallable |
Interfaces: | Infrared interface serial RS232 interface |
Language: | Operator prompting and documentation in German, English, French (other languages optional) |
Surface temperature: | -15 °C to 60 °C / 5 °F to 140 °F optional up to 150 °C / 302 °F |
Operating temperature: | 0 °C to 50 °C / 32 °F to 122 °F |
Storage temperature: | -20 °C to +60 °C / -4 °F to 140 °F |
Power supply: | 2 x Mignon cells (AA) 1.5V up to 60 hours of operating time |
Housing/keypad: | Protection class IP52 (protection against dust and dripping water) |
Dimensions: | Gauge: 137 mm x 66 mm x 23 mm/5.4" x 2.6" x 0.9" (HxWxD)
probes FN 1.5, F 1.5, N 1.5, FN 0.2: dia. 14 mm x 83 mm / dia. 0.56" x 3.3"
probes FN 3.5, F 3.5: dia. 25 mm x 47 mm/ dia. 1" x 1.8"
probe F 10: dia. 25 mm x 48 mm/ dia. 1" x 1.9"
probe FN1.5/90°: 8 mm x 10 mm x 180 mm/ 0.3" x 0.4" x 7.0" (HxWxD)
|
Weight: | Gauge: approx. 155 g / 5.5 ozs incl. batteries probes FN 1.5, F 1.5, N 1.5, FN 0.2: approx. 70 g / 2.5 ozs probes FN 3.5, F 3.5: approx. 105 g / 3.7 ozs probe F 10: approx. 85 g / 3.0 ozs probe FN1.5/90°: approx. 80 g / 2.8 ozs |
Standards: | DIN EN ISO, ASTM, BS |